Inspections & Testing

When people require their electrics to be checked, they often call it different things:

What they are asking for in all these cases is an in-service, inspection and more importantly Test of their Electrical installation. This is known as only one thing in the IEE wiring regulations - a Electrical Installation Condition Report.

The IEE Wiring Regulations recommend that an Electrical Installation Condition Report should be considered for the following reasons:

  • A change of occupancy of the premises.
  • A change of use of the premises.
  • After alterations or additions to the original installation.
  • Where there is reason to believe that damage may have been caused to the installation.

The title for the Test Report Changed in 2014 under updated IEE Electrical Regulations.  It is now called an "Electrical Installation Condition Report"  (EICR) -it is aptly named as that is what it is, it gives the findings of an Electrical Installation which has been tested - It is NOT a Safety Certificate. Where works are carried out after the EICR to bring the installation up to a safe standard, then the report will give evidence of a satisfactory Installation.

What happens when an Inspection and test is carried out?

A series of visual checks ae carried out on the electrical installation.  Circuit breaker will be checked to ensure they are of the correct type and rating to protect the outgoing cable. The cables will be checked for current carrying capacity and voltage drop. Signs of damage, burning etc., will be looked for. 10% of all sockets, switches etc., are opened up and inspected. If there are any non-compliances found, then even more and probably all of the accessories are then checked.

The Inspection is followed by the tests. 100% of the installation is tested. Several electrical measurements are recorded on the report including continuity of circuit protective conductors, main and supplementary earth bonding, continuity of ring final circuit conductors, insulation resistance, polarity, earth-fault loop impedance, RCD tests including trip time in milliseconds, correct operation of switches, and isolators, protective fault current.

The installation is then declared Satisfactory or Unsatisfactory. Many installations are found to be satisfactory, but are to older regulations, and would benefit from being upgraded. If this is the case then we would advise you of the best way to comply with current standards.

Rates & Fixed Prices

Our Pricing & Rates are Transparent to all Customers. Please see Pricing

For further Information, please do not hesitate to contact us.

Telephone: 01892 531728

Email: karen@brightsparkelectrician.co.uk

We are very pleased with Phillip’s work. You’ve truly gone above and beyond to deliver what we had in mind for our front porch.

Maria - Tonbridge

Our timer on our central heating went and my husband was miles away at work,it was early evening when I phoned karen, but straight away she told me not to worry,to send a photo of the timer and she'd sort it out,and she did, an electrician came out with a new timer fitted it and was gone, brilliant service from start to finish, will definitely use them again and would highly recommend them

Di, Paddock Wood

Thank you also for such a brilliant service, it’s been a pleasure dealing with you from start to finish, and your team member today was fantastic too. I would have absolutely no hesitation using you for electrical work in future and recommending you to friends. Now, if you could just set up a building and plumbing company too… ha ha!

Louise - St James

Karen and her team provide a very efficient, friendly and pro-active service with a smile! We would not hesitate in recommending Bright Spark and fully intend to use them in the future for our electrical requirements."

Sarah & Derek - Lamberhurst

Karen arrived shortly after my phone call, all sorted. Very happy, thank you.

Martin, Tunbridge Wells

REQUEST QUOTE