Adequate provision of Electrical Socket outlets in the Home

The increased use of home electronics and entertainment systems has led to the situation that, not only are homeowners using extension leads for their TV area but also for many other areas in their homes. Homeowners and clients always prefer an increased number of socket outlets; surveys have shown that 50% of new homeowners require additional socket outlets within twelve months of purchase of a new dwelling.

History

A Report of the Electrical Installation Industry Liaison Committee (EIILC), first published in 1977, made proposals for the minimum number of socket-outlets, which should be provided in homes.

These proposals were made particularly on the grounds of safety - safety for the user, the installation itself, the home and of property - and for maintaining that level of safety during the life of the installation whilst allowing for the changing needs of the user.

This EIILC report has been extended to also cover the minimum requirements for existing and foreseen standards of living and the use of electrical and electronic equipment in the average home.

The use of such equipment in the home has increased dramatically as can be seen from the chart overleaf. The minimum requirements advocated in this Report are to be found in Table 1, which covers all types of dwelling e.g. public housing, affordable housing and private development.

Increased use of Electrical Consumer Equipment

The chart, which follows, illustrates the significant increase in consumer equipment, which has driven the need for increased number of socket-outlets.

Three or more television sets in one home are commonplace together with home entertainment systems, DVD/video recording equipment - which usually remains plugged in - and also the use of home computers and peripheral devices.

In the last seven years the use of electrical equipment in dwellings has increased dramatically as shown. Some electric equipment, which was formerly battery operated is now available in a mains/battery form and this equipment often remains, connected to the mains via its charger.

Safety

It has already been stated that the number of socket-outlets being advocated is primarily on the grounds of safety. The resulting dangers of not having sufficient socket-outlets may be summarized as follows:

  • 'Do-it yourself' extension to the circuit will be attempted
  • DIY extension to the flex of the equipment
  • Cascading (daisy chaining) of extension leads
  • Inappropriate stacking of adaptors

All of the above will create potential hazards, namely risk of electric shock or injury and damage to property through fire.

Legal Requirements: Building Regulations

Electrical installation work carried out in dwellings in England and Wales is subject to BS7671 IEE Wiring Regulations and to Part P of the Building Regulations, which requires that:

"Reasonable provision shall be made in the design and installation of electrical installations in order to protect persons operating, maintaining or altering installations from fire or injury".

Adequate provision of Socket-Outlets

An inadequate number of socket-outlets will lead to an increased hazard due to the consumer being encouraged to cascade extension leads and / or stack adaptors.

This can be avoided by ensuring that an adequate number of socket-outlets as stated in this guide are installed and suitably located. There is now a legal requirement under Part M of the Building Regulations that reasonable provision shall be made for people to-

a.   Gain access to; and
b.   Use the building and its facilities.

Clearly if socket-outlets are not conveniently located they will not be used. They need to be suitably distributed around the room, due account being taken of furniture, electrical equipment and future change of use.

Notes

1. Kitchen ~

If a socket outlet is provided in the cooker control unit, this should not be included in the 6 recommended in the table above.

Appliances built into kitchen furniture (integrates appliances) should be connected to a socket- outlet or switch fused connection unit that is accessible when the appliance is in place and in normal use.  Alternatively when an appliance is supplied from a socket-outlet or a connection unit, these should be controlled by an accessible double pole switch o r switched fused connection unit,

It is recommended that a wall mounted socket-outlet above a work surface be spaced at not more than 1-meter intervals along the surface.

2. Garage ~

The number of socket-outlets specified allows for the use of a battery charger, tolls, portable light and garden appliances.

3. Bedroom ~

It is envisaged that this room will be used in different ways in different households. It may be used simply as a child’s bedroom requiring socket-outlets for table lamps, and electric blanket and an electric heater only; or it may serve as a teenager’s bedroom and living room combined, where friends are entertained.  In this case, socket outlets may be needed for computers (printers, scanners, speakers etc.), games consoles, MP3/players, mobile phone chargers, DVD players, Digital receivers home entertainment systems (amplifiers, CD Player) hairdryer, televisions and radio, in addition to lamps, an electric blanket and electric heater.

4. Home entertainment ~

In addition to the number of socket outlets shown in the table it is recommended that at least two further double socket outlets are installed in home entertainment areas.

5. Locations containing a Bath or Shower ~

Socket outlets other than SELV socket-outlets and shaver supply units complying with BS EN 61558-2-5 are prohibited with a distance of 3 meters horizontally from the boundary zone 1 e.g. 230V socket-outlets in a bathroom must be installed a minimum 3metres from the edge of the Bath, BS 7671 (IEE Wiring Regulations) refers.

6. Bedsitting room ~

Rooms specifically designed or envisaged to be used as student bedsitting rooms should be provided with additional socket outlets, which may be needed since persons using these rooms will often introduce, other portable appliances in addition to items already mention in Note 3. In such situations a lack of sufficient socket outlets is an additional danger and there the minimum number of twin outlets should be increased to 4.

 

Recent Articles

We are very pleased with the high standard of the recent work carried out by Bright Spark and would happily recommend the service. We were particularly impressed by the quick response to our online enquiry and the email follow up by Karen after the job had been completed. We will definitely use her for any electrical job in the future.

Katie, Tonbridge

Thank you very much, and please pass on my thanks to Philip who completed the job. I appreciate it was an awkward space for him to work on, but everything was done so well and so quickly - I am very happy with the outcome! Will be returning to you for more jobs soon I’m sure!

Rebecca - Tonbridge

We were very pleased with the recent electrical work which was carried out in a professional manner by your electrician and will certainly use your company again when future needs arise. Also I would be happy to recommend your services to any of our friends.

Tony, Tunbridge Wells

"I have had Bright Sparks at my property twice in the last six months to complete some electrical work. I have been blown away by the innovative efficient way I am communicated with the efficiency and ease of the process. The work has been carried out to a more than satisfactory standard and I found it to be extremely competitively priced. It is by far the best experience I have had with any service provider in forever. Thanks guys."

Andrea - Sevenoaks

I was really impressed with the work done for me by Bright Sparks. It is lovely that they are local to me in Hildenborough and grateful that they could fit me in at short notice. The repairs were done quickly and easily by Charlie and the whole thing coordinated by Karen who kept me informed every step of the way. Well done Bright Sparks!

Jill - Hildenborough

REQUEST QUOTE